Actuators and sensors for FPSO, ship-building, offshore, onshore Actuators and sensors for HVAC systems, sewage plants, landfills, power plants Actuators and sensors for chemistry, pharmacy and general industry Certification with highest protection classes Schischek contact worldwide Schischek GmbH Explosionproof – Home Schischek GmbH Explosionproof – Home

Company

you are here

Products/Solutions

Explosion Proof

Application Areas

Service/Downloads

Contact

Products | Binary electric digital sensors ExBin.. Schischek GmbH ExplosionproofEx..Red..In..CT/OCT..

Binary electric digital sensors for Ex-areas
ATEX 94/9/EC | zone 1, 2, 21, 22

ExBin-P pressure/differential low pressure switch (pressostat)

Binary pressure/differential pressure switch ΔP
Low pressure sensor (Pressostat)

NEW: Binary differential pressure switch ExBin-P-100 with adjustable switch activation delay, for low pressure from 0-100 Pa
Measurements ..Bin-P Sensor: L × B × H = 177 × 107 × 66 mm

Measurements in mm

Description – Binary digital differential pressure switch (Pressostat) ExBin-P..

  • Binary electric digital pressure switches (Pressostats) for HVAC systems, e.g. for differential pressure control for filter- or fan belt monitoring
  • No additional module in the panel required!
  • No intrinsically safe wiring required!
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Pressostat ExBin-P-100 with differential pressure range from 0 - 100 Pa allows an achievement of new applications with a smaller differential pressure range
  • Additionally the ExBin-P-100 has an adjustable switch activation delay contact for applications which require a time-delayed fault indication, for example short opening of doors in clean room environment

ExBin-P..

0...100 Pa, 0...500 Pa, 0...5.000 Pa1-channel or 2-channel adjustable15.000 Pa...50.000 Pa24 VAC / DCPotential free switching contact adjustable per menuadjustable from 0...240 s (factory setting:
0 s = switch activation delay off)
LCD Backlight, defeatable
Switching status LEDs
IP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated Ex-e terminal boxca. 950 gGases, mists, vapours, dustZone 1, 2, 21, 22II2(1)G Ex emb [ia] IIC T6II2(1)D Ex tD A21 [iaD] IP66 T80°C1 ExBin-P-100 only 1-channel

Delivery – ExBin-P..

  • Pressure switch (Pressostat) with integrated Ex-e terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • 1 × Short circuit tube ca. 140 mm length

Special models – ExBin-P... - 2

  • Pressure switch with two switching outputs (2 × potential free contacts)

Accessories – ExBin-P..

  • „Installation kit 2“ includes 2 m pressure hose Ø 6 mm inner diameter,
    2 plastic fittings
  • Mounting-bracket for installation on round air-ducts up to Ø 600 mm
ExBin-FR frost protection thermostat – binary, activ

Frost protection thermostat – binary, activ°C

Measurements ..Bin-FR Sensor: L × B × H = 177 × 107 × 66 mm

Measurements in mm

Description – Binary electric digital frost protection thermostat ExBin-FR..

  • Binary electric digital frost protection thermostats for HVAC systems, e.g. frost protection monitoring of heating registers / heat exchangers
  • No additional module in the panel required!
  • No intrinsically safe wiring required!
  • Switch-point mechanically adjustable

ExBin-FR..

-10 °C...+15 °C1-stage (1-channel)3 meters or 6 meters24 VAC / DC~ 40 cm1 potential-free contactSwitching status with LEDsIP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated Ex-e terminal boxca. 950 gGases, mists, vapours, dustZone 1, 2, 21, 22II2(1)G Ex emb [ia] IIC T6II2(1)D Ex tD A21 [iaD] IP66 T80°C

Delivery – ExBin-FR..

  • Frost protection thermostat with integrated Ex-e terminal box and 3 m
    or 6 m capillary (dependent by Type)
  • 3 × Tapping screw Ø 4,2 × 13 mm

Accessories – ExBin-FR..

  • „Installation kit 1.3“: Cappillary duct, assembly cramp and 4 assembly brackets (for ExBin-FR3)
  • „Installation kit 1.6“: Cappillary duct, assembly cramp and 8 assembly brackets (for ExBin-FR6)
  • Mounting-bracket for installation on round air-ducts up to Ø 600 mm
ExBin-N Fan belt monitoring via speed control

Fan belt (V-belt) monitoring, binary Umin
via contactless speed control

Measurements ..Bin-N Sensor: L × B × H = 177 × 107 × 66 mm

Measurements in mm

Description – Fan belt (Drive belt) guard via speed control ExBin-N..

  • Binary electric digital fan belt monitoring modul (V-belt guard) for HVAC systems, via speed control of fan drive shaft
  • No additional module in the panel required!
  • No intrinsically safe wiring required!
  • Switch-point in min¹ is digitally adjustable
  • Integrated, adjustable time switch relais

ExBin-N..

0...10.000 min¹1-stage or 2-stage, 50...10.000 min¹24 VAC / DCNamur transducer inductive, DIN 19234Potential free switching contact adjustable per menuLCD Backlight, defeatable
Switching status LEDs
IP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated Ex-e terminal boxca. 950 gGases, mists, vapours, dustZone 1, 2, 21, 22II2(1)G Ex emb [ia] IIC T6II2(1)D Ex tD A21 [iaD] IP66 T80°C

Delivery – ExBin-N..

  • Fan belt monitoring modul with integrated terminal box and directly mountable Namur transducer
  • 3 × Tapping screw Ø 4,2 × 13 mm

Special models – ExBin-N-2

  • Version with 2-stage switch point (2 × potential-free contacts)

Accessories – ExBin-N..

  • „Installation kit 3“: Mountingset for Namur transducer onto ventilators /
    propellers up to approx. 20.000 m³/h (Empirical values – they can vary depending on the construction of ventilator / propeller)
  • „Installation kit 4“: Mountingset for Namur transducer onto ventilators /
    propellers over approx. 20.000 m³/h (Empirical values...)
  • Mounting-bracket for installation on round air-ducts up to Ø 600 mm
ExBin-D Thermostat / Hygrostat, binary

Thermostat / Hygrostat – binary°C %rH

Description – Binary electric digital thermostat / hygrostat ExBin-D..

  • Binary electric digital module for connection of one ExPro-B.. sensor
    probe, use as thermostat or hygrostat in HVAC systems
  • No additional module in the panel required!
  • No intrinsically safe wiring required!
  • Selectable on site if used for room or duct application!
  • Switch-point for °C and %rH is separately adjustable (dependent on
    sensor probe type)
  • Adjustable directly on site without additional tools / meas. devices

ExBin-D..

-40 °C...+125 °C0...100 %rHRoom- and / or Duct-measurement24 VAC / DC1 × ExPro-B.. sensor probePotential free switching contact adjustable per menuLCD Backlight, defeatable
Switching status LEDs
IP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated Ex-e terminal boxca. 950 gGases, mists, vapours, dustZone 1, 2, 21, 22II2(1)G Ex emb [ia] IIC T6II2(1)D Ex tD A21 [iaD] IP66 T80°C

Delivery – ExBin-D..

  • Module (Thermostat/Hygrostat) with integrated terminal box and socket
    for one ExPro-B.. sensor probe
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Required accessory: ExPro-B.. sensor probe

Special models – ExBin-D-2

  • Module with 4-stage output (4 pot.-free contacts = 2 × °C, 2 × %rH)

Accessories – ExBin-D..

ExPro-B.. digital sensor probes, suitable for ExBin-D/RedBin-D Thermostat/Hygrostat
ExBin-A Switching module, binary

Switching modules – binary°C %rH ΔP

Description – Binary electric digital switching module ExBin-A..

  • Binary electric digital switching modules for direct mounting in Ex areas
  • Use in HVAC systems (Heating, Ventilating and Air Conditioning)
  • Connection of 1, 2 or 5 passive, potential-free binary sensors
  • No additional module in the panel required!
  • No intrinsically safe wiring required!

ExBin-A..

24 VAC / DCThermostats TBR-2.., TBK.., TBT..
Humiditystats FBR-2G.., FBK-2G..
Diff. pressure switch DBK..,
Air flow switch WFBK-2G..
Frost protection thermostat TBK-FR-2G..
Potential-free switching contactActual value indication LEDsIP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated Ex-e terminal boxca. 950 gGases, mists, vapours, dustZone 1, 2, 21, 22Zone 0, 1, 2, 20, 21, 22II2(1)G Ex emb [ia] IIC T6II2(1)D Ex tD A21 [iaD] IP66 T80°C

Delivery – ExBin-A..

  • Switching module with socket for 1, 2 or 5 binary ExSens sensors (dependent on type)
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Optional accessory: Binary sensors series ExSens

Accessories – ExBin-A..

  • Mounting-bracket for installation on round air-ducts up to Ø 600 mm
back to Product choice
to the top

Schischek News

New content on Schischek Homepage

Colour Code

Products for
zone 1, 2, 21, 22
(e.g. ExMax+LIN)

Products for
zone 2, 22
(e.g. RedMax+LIN)

Products for
safe area
(e.g. InMax+LIN)

Amercoat (Marine) painted versions
(e.g. ..Cos..-CT / OCT)

Stainless steel versions AISI 316
(e.g. RedMax-..-VAS)