Actuators and sensors for FPSO, ship-building, offshore, onshore Actuators and sensors for HVAC systems, sewage plants, landfills, power plants Actuators and sensors for chemistry, pharmacy and general industry Certification with highest protection classes Schischek contact worldwide Schischek GmbH Explosionproof – Home Schischek GmbH Explosionproof – Home

Company

Products/Solutions

Explosion proof

Application areas

Service/Downloads

Contact

Products | Industrial modulating digital sensors InCos.. Schischek GmbH ExplosionproofEx..Red..In..CT/OCT..

Industrial modulating digital sensors for safe area
Protection class IP66 | not Explosion proof

InCos-P Differential pressure-/VAV-sensors

Differential pressure-/VAV-Sensors ΔP

Measurements ..Cos-P Sensor: L × W × H = 180 × 107 × 66 mm

Measurements in mm

Description – Modulating digital differential pressure sensor InCos-P-..

  • Modulating electric digital pressure sensors for HVAC systems, e.g. for differential pressure control in safe area
  • VAV control optional
  • No additional module in the panel required!
  • No intrinsically safe wiring required!
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Integrated actual value indication, illuminated, can be switched off
  • Integrated terminal box
  • Robust aluminium housing with protection class IP66

InCos-P

± 100 Pa...± 7.500 Pa20 Pa25.000 Pa...120.000 Pa24 VAC / DC0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHover integrated terminal boxca. 1040 gSafe area

Delivery – InCos-P..

  • 1 × Modulating digital sensor InCos-P with integrated terminal box for differential pressure or volume flow control (VAV)
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • 1 × Short circuit tube ca. 140 mm length

Special models – InCos-P..-A

  • Module with one 4-20 mA output to connect external actual value indicator

Accessories – InCos-P..

  • External LCD indicator connectable to InCos-P..-A sensors,
    mounting in safe area
  • Mounting-bracket for installation on round air-ducts up to Ø 600 mm
  • „Installation kit 2“ includes 2 m pressure hose Ø 6 mm inner diameter,
    2 plastic fittings
InCos-D Temperature-/humidity transducer

Temperature-/humidity transducer°C,%rH
Combination with InPro-C.. digital sensors

Description – Modulating digital temperature / humidity transducer InCos-D

  • Modulating electric digital transducer for measurements of temperature and/or humidity together with InPro-C.. digital sensor probes in HVAC systems, installation in safe area
  • Connector for InPro-C.. sensor probes for room or duct mounting
  • No additional module in the panel required!
  • No intrinsically safe wiring required!
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Integrated actual value indication, illuminated, can be switched off
  • Integrated terminal box
  • Robust aluminium housing with protection class IP66

InCos-D

-40 °C...+125 °C0...100 %rHRoom- and / or Duct-measurement24 VAC / DC1 × InPro-C.. Sensor0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHover integrated terminal boxca. 1040 gSafe area

Delivery – InCos-D..

  • 1 × Modulating digital module InCos-D with integrated terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Required accessory: InPro-C.. Sensor

Special models – InCos-D-A

  • Module with two 4-20 mA outputs to connect external actual value
    indicator (Output 1 for °C, Output 2 for %rH)

Accessories – InCos-D..

  • InPro-C.. digital sensors
  • External LCD indicator connectable to InCos-DA transducer,
    mounting in safe area
  • Mounting-bracket for installation on round air-ducts up to Ø 600 mm
InPro-C.. digital sensors, compatible with InCos-D transducer
InCos-A Temperature-/humidity transducer

Temperature-/humidity transducer°C, %rH
Combination with passive sensors

Measurements ..Cos-A Sensor: L × W × H = 180 × 107 × 66 mm

Measurements in mm

Description – Modulating digital temperature / humidity transducer InCos-A

  • Modulating electric digital transducer for measurements of temperature or humidity together with modulating passive sensors in HVAC systems, module installation in safe area
  • Connector for one modulating passive sensor for room or duct mounting
  • No additional module in the panel required!
  • No intrinsically safe wiring required!
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Integrated actual value indication, illuminated, can be switched off
  • Integrated terminal box
  • Robust aluminium housing with protection class IP66

InCos-A

24 VAC / DCmodulating, passive, potential free:
Pt 100, Pt 500, Pt 1000, Ni 100, Ni 200,
Ni 500, Ni 1000, Ni 1000 Siemens, KP 250, Resistance output 0...1 kOhm, 0...10 kOhm
0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHover integrated terminal boxca. 1040 gSafe area

Delivery – InCos-A..

  • 1 × Modulating digital sensor InCos-A with integrated terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Required accessory: passive sensor

Special models – InCos-A-A

  • Module with one additional 4-20 mA output to connect a external actual value indicator

Accessories – InCos-A..

  • External LCD indicator connectable to InCos-A-A transducer,
    mounting in safe area
  • Mounting-bracket for installation on round air-ducts up to Ø 600 mm
back to Product choice
to the top

Schischek News

New content on Schischek Homepage

Colour Code

Products for
zone 1, 2, 21, 22
(e.g. ExMax+LIN)

Products for
zone 2, 22
(e.g. RedMax+LIN)

Products for
safe area
(e.g. InMax+LIN)

Amercoat (Marine) painted versions
(e.g. ..Cos..-CT / OCT)

Stainless steel versions AISI 316
(e.g. RedMax-..-VAS)