Schischek Linie
German | English | Français Home | General terms and conditions | Contact | Sitemap
Schischek Linie
 
Products | Binary sensors RedBin.. Schischek GmbH ExplosionproofEx..Red..In..

Binary sensors for Ex-areas
ATEX 94/9/EC | zone 2, 22

RedBin-P pressure/differential pressure switch (pressostat)

Binary pressure/diff. pressure switch (Pressostat) ΔP

Measurements ..Bin-P Sensor: L × B × H = 177 × 107 × 66 mm

Measurements in mm

Description – Binary differential pressure switch (Pressostat) RedBin-P..

  • Pressure switches for HVAC systems, e.g. for differential pressure control for filter- or fan belt monitoring
  • No additional module in the panel required!
  • No intrinsically safe wiring required!
  • All parameters adjustable on site w/o additional tools/meas. devices

RedBin-P..

0 - 500 Pa, 0 - 5.000 Pa1-channel or 2-channel adjustable5.000 Pa - 50.000 Pa24 VAC / DCPotential free switching contact adjustable per menuLCD Backlit, defeatable
Switching status LEDs
IP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated Ex-e terminal boxca. 950 ggases, mists, vapours, dustzone 2, 22II3(1)G Ex nC [ia] IIC T6II3(1)D Ex tD A22 [iaD] IP66 T80°C

Delivery – RedBin-P..

  • Pressure switch with integrated Ex-e terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • 1 × Short circuit tube ca. 140 mm length

Special models – RedBin-P... - 2

  • Pressure switch with two switching outputs (2 × potential free contacts)

Accessories – RedBin-P..

  • „Installation kit 2“ includes 2 m pressure hose Ø 6 mm inner diameter,
    2 plastic fittings
  • Mounting-bracket for installation on round air-ducts up to Ø 600 mm
RedBin-FR frost protection thermostat – binary, activ

Frost protection thermostat – binary, activ°C

Measurements ..Bin-FR Sensor: L × B × H = 177 × 107 × 66 mm

Measurements in mm

Description – Frost protection thermostat RedBin-FR..

  • Frost protection thermostats for HVAC systems, e.g. frost protection monitoring of heating registers / heat exchangers
  • No additional module in the panel required!
  • No intrinsically safe wiring required!
  • Switch-point mechanically adjustable

RedBin-FR..

-10 °C...+15 °C1-stage (1-channel)3 meters or 6 meters24 VAC / DC~ 40 cm1 potential-free contactSwitching status with LEDsIP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated Ex-e terminal boxca. 950 ggases, mists, vapours, dustzone 2, 22II3(1)G Ex nC [ia] IIC T6II3(1)D Ex tD A22 [iaD] IP66 T80°C

Delivery – RedBin-FR..

  • Frost protection thermostat with integrated Ex-e terminal box and 3 m
    or 6 m capillary (dependent by Type)
  • 3 × Tapping screw Ø 4,2 × 13 mm

Accessories – RedBin-FR..

  • „Installation kit 1.3“: Cappillary duct, assembly cramp and 4 assembly brackets (for RedBin-FR3)
  • „Installation kit 1.6“: Cappillary duct, assembly cramp and 8 assembly brackets (for RedBin-FR6)
  • Mounting-bracket for installation on round air-ducts up to Ø 600 mm
RedBin-N Fan belt monitoring via speed control

Fan belt monitoring, binary Umin
via contactless speed control

Measurements ..Bin-N Sensor: L × B × H = 177 × 107 × 66 mm

Measurements in mm

Description – Fan belt guard via speed control RedBin-N..

  • Fan belt monitoring modul (V-belt guard) for HVAC systems, via speed control of fan drive shaft
  • No additional module in the panel required!
  • No intrinsically safe wiring required!
  • Switch-point in min¹ is digitally adjustable
  • Integrated, adjustable time switch relais

RedBin-N..

0 - 10.000 min¹1-stage or 2-stage, 50 - 10.000 min¹24 VAC / DCNamur transducer inductive, DIN 19234Potential free switching contact adjustable per menuLCD Backlit, defeatable
Switching status LEDs
IP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated Ex-e terminal boxca. 950 ggases, mists, vapours, dustzone 2, 22II3(1)G Ex nC [ia] IIC T6II3(1)D Ex tD A22 [iaD] IP66 T80°C

Delivery – RedBin-N..

  • Fan belt monitoring modul with integrated terminal box and directly mountable Namur transducer
  • 3 × Tapping screw Ø 4,2 × 13 mm

Special models – RedBin-N-2

  • Version with 2-stage switch point (2 × potential-free contacts)

Accessories – RedBin-N..

  • „Installation kit 3“: Mountingset for Namur transducer onto ventilators /
    propellers up to approx. 20.000 m³/h (Empirical values – they can vary depending on the construction of ventilator / propeller)
  • „Installation kit 4“: Mountingset for Namur transducer onto ventilators /
    propellers over approx. 20.000 m³/h (Empirical values...)
  • Mounting-bracket for installation on round air-ducts up to Ø 600 mm
RedBin-D Thermostat / Hygrostat, binary

Thermostat / Hygrostat – binary°C %rH

Description – Thermostat / Hygrostat RedBin-D..

  • Use together with ExPro-B.. sensor probe as thermostat or hygrostat in HVAC systems
  • No additional module in the panel required!
  • No intrinsically safe wiring required!
  • Selectable on site if used for room or duct application!
  • Switch-point for °C and %rH is separately adjustable (dependent on sensor probe type)
  • Adjustable directly on site without additional tools / meas. devices

RedBin-D..

-40 °C...+125 °C0...100 %rHRoom- and / or Duct-measurement24 VAC / DC1 × ExPro-B.. sensor probePotential free switching contact adjustable per menuLCD Backlit, defeatable
Switching status LEDs
IP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated Ex-e terminal boxca. 950 ggases, mists, vapours, dustzone 2, 22II3(1)G Ex nC [ia] IIC T6II3(1)D Ex tD A22 [iaD] IP66 T80°C

Delivery – RedBin-D..

  • Module with integrated terminal box and socket for one ExPro-B..
    sensor probe
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Required accessory: ExPro-B.. sensor probe

Special models – RedBin-D-2

  • Module with 4-stage output (4 pot.-free contacts = 2 × °C, 2 × %rH)

Accessories – RedBin-D..

ExPro-B.. digital sensor probes, suitable for ExBin-D/RedBin-D Thermostat/Hygrostat
RedBin-A Switching module, binary

Switching modules – binary°C %rH ΔP

Description – Switching module RedBin-A..

  • Switching modules for direct mounting in Ex areas
  • Use in HVAC systems (Heating, Ventilating and Air Conditioning)
  • Connection of 1, 2 or 5 passive, potential-free binary sensors
  • No additional module in the panel required!
  • No intrinsically safe wiring required!

RedBin-A..

24 VAC / DCThermostats TBR-2.., TBK.., TBT..
Humiditystats FBR-2G.., FBK-2G..
Diff. pressure switch DBK..,
Air flow switch WFBK-2G..
Frost protection thermostat TBK-FR-2G..
Potential-free switching contactActual value indication LEDsIP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated Ex-e terminal boxca. 950 ggases, mists, vapours, dustzone 2, 22zone 0, 1, 2, 20, 21, 22II3(1)G Ex nC [ia] IIC T6II3(1)D Ex tD A22 [iaD] IP66 T80°C

Delivery – RedBin-A..

  • Switching module with socket for 1, 2 or 5 binary ExSens sensors (dependent on type)
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Optional accessory: Binary sensors series ExSens

Accessories – RedBin-A..

  • Mounting-bracket for installation on round air-ducts up to Ø 600 mm
back to Product choice

Products for
zone 1, 2, 21, 22
(Example ExMax)

Products for
zone 2, 22
(Example RedMax)

Products for
safe area
(Example InMax)

 
 
 
 
Actuators and sensors for ship building, offshore, onshore, FPSO Actuators and sensors for HVAC systems (heating, ventilation, airconditioning), climate control Actuators and sensors for chemistry, pharmacy, industry Actuators and sensors for power plants, water treatment, landfills Schischek contact worldwide Schischek GmbH Explosionproof – Home Schischek GmbH Explosionproof – Home