Special versionsLabel for the special versionsLabel.PropertiesS1Drive unit without anti-backdrive mechanism (drive can be turned back by external load when the power is switched off).Cable length 1.5 m S2No thermal cutoff (only available as InMax)S3To +60 °CRestrictionsfor ExMax and RedMax: Temperature class T4only suitable for 110 V ... 240 Vmaximum 25 % duty cyclecannot be supplied for Y drivesS7Only for InMaxDrive unit without anti-backdrive mechanism (drive can be turned back by external load when the power is switched off).Max-S with aluminium housing with additional damping elements, maximum load 500 gS9No thermal cutoff (only available as InMax)Limit switch configured to 0/80° instead of 5/85° S12Drive unit without anti-backdrive mechanism (drive can be turned back by external load when the power is switched off).S14To +60 °CRestrictionsfor ExMax and RedMax: Temperature class T4only suitable for 110 V ... 240 Vcannot be supplied for Y drivesS17Cable length 3.0 mS18Drive unit without anti-backdrive mechanism (drive can be turned back by external load when the power is switched off).Angle of rotation limited to 90 ° by the drive itselfS27To +60 °CRestrictionsfor ExMax and RedMax: Temperature class T4only suitable for 110 V ... 240 Vmaximum 25 % duty cyclecannot be supplied for Y drivesNo regulation, just positioningonly for InMaxcan only be supplied for Y drivesS30Cable length 1.5 mIncludes KIT protective hose VAS31To +60 °C 24 VAC/DCRestrictionsfor ExMax and RedMax: Temperature class T4maximum 15 % duty cyclecannot be supplied for Y drivesS32Drive unit without anti-backdrive mechanism (drive can be turned back by external load when the power is switched off).Max-S with aluminium housing with additional damping elements, maximum load 500 gCable length 3.0 mTo +60 °CRestrictionsfor ExMax and RedMax: Temperature class T4only suitable for 110 V ... 240 Vmaximum 25 % duty cyclecannot be supplied for Y drivesS33Cable length 3.0 mTo +60 °CRestrictionsfor ExMax and RedMax: Temperature class T4only suitable for 110 V ... 240 Vmaximum 25 % duty cyclecannot be supplied for Y drivesS36Drive unit without anti-backdrive mechanism (drive can be turned back by external load when the power is switched off).Max-S with aluminium housing with additional damping elements, maximum load 500 gCable length 3.0 mS38Cable length 3.0 mTo +60 °CRestrictionsfor ExMax and RedMax: Temperature class T4only suitable for 110 V ... 240 Vmaximum 25 % duty cyclecannot be supplied for Y drives