Rotork-Schischek contact worldwide Certification with highest protection classes Applications for chemistry, pharmacy and general industry Applications for HVAC systems, sewage plants, landfills, power plants Applications for FPSO, ship-building, offshore, onshore Rotork-Schischek – Home Rotork-Schischek – Home

Company

you are here

Products/Solutions

Explosion Proof

Application Areas

Service/Downloads

Contact

Products | Analog sensors & transmitter ExCos.. Schischek GmbH ExplosionproofEx..Red..In..CT/OCT..

Analog, Electric Sensors and Transmitter ExCos for Hazardous Locations
ATEX 2014/34/EU | Explosion proof | zone 1, 2, 21, 22

ExCos-V

Volume flow (Diff.pressure) transmitter ΔP

ExCos-V-CT with seawater resistant offshore/marine coating

Offshore/marine coated ExCos-V-CT

Ex-area

Description – Analog volume flow ATEX transmitter ExCos-V

  • Analog volume flow (differential pressure) transmitter for applications in hazardous locations zone 1, 2, 21, 22 for measuring and display of volume flows in ventilation systems (HVAC)
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • Adjustable „k-factor“
  • Switch-on delay 3 seconds
  • Air volume and alarm monitoring
  • Additional switching contact
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Integrated actual value indication, illuminated, can be switched off
  • Integrated terminal Ex-e box
  • Robust aluminium housing with protection class IP66
  • Optional available in stainless steel (AISI 316) or with offshore/marine coating

ExCos-V

0...100 Pa / 0...300 PaDifferential pressure3 seconds24 VAC/DC1 × 0(4)...20 mA, 1 × 0(2)...10 V, 1 × RelaisBacklight, defeatableIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHover integrated Ex-e terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgGases, mists, vapours, dustZone 1, 2, 21, 22ATEX

Delivery – ExCos-V..

  • 1 × Analog volume flow transmitter ExCos-V with display and integrated Ex-e terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • 1 × Short circuit tube ~ 140 mm length

Special model in stainless steel – ExCos-V-...-VA

  • Stainless steel housing AISI 316, some parts nickel plated

Special model in stainless steel – ExCos-V-...-OVA

  • Offshore version with aluminium housing, pressure conection and screws
    in seawater resistant robust stainless steel (AISI 316), M20 cable glands nickel-plated

Special model painted (coated) – ExCos-V-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel (AISI 316)

Special model painted (coated) – ExCos-V-...-OCT

  • Offshore version with aluminium housing offshore/marine coated, seawater resistant, cable glands nickel plated, tubes for clamping ring
    Ø 6 mm and screws in stainless steel (AISI 316)

Accessories – ExCos-V..

  • Mounting bracket for round air ducts up to Ø 600 mm
  • Installation kit with 2 m flexible pressure hose Ø 6 mm
  • Stainless steel pressure tube connection for 6 mm clamp fittings
  • M16 standard cable glands in brass nickel plated
  • M20 Ex-d cable glands in brass nickel plated for armoured cables
    (Offshore applications)
ExCos-P

Differential pressure sensors ΔP

Description – Analog differential pressure sensor ExCos-P-..

  • Analog electric pressure sensors for HVAC systems, e.g. for differential pressure control in hazardous locations zone 1, 2, 21, 22
  • Volume flow applications optional
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Integrated actual value indication, illuminated, can be switched off
  • Integrated Ex-e terminal box
  • Robust aluminium housing with protection class IP66
  • Optional available in stainless steel (AISI 316) or with offshore/marine coating

ExCos-P

± 100 Pa...± 7.500 Pa20 Pa25.000 Pa...120.000 Pa24 VAC / DC0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHover integrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgGases, mists, vapours, dustZone 1, 2, 21, 22ATEX, IECEx, EAC, KOSHA

Delivery – ExCos-P..

  • 1 × Analog sensor ExCos-P with integrated Ex-e terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • 1 × Short circuit tube ~ 140 mm length

Special models – ExCos-P..-A

  • Module with one intrinsically 4..20 mA output to connect external actual value indicator

Special model in stainless steel – ExCos-P-...-VA

  • Stainless steel housing AISI 316, some parts nickel plated

Special model in stainless steel – ExCos-P-...-OVA

  • Offshore version with aluminium housing, pressure conection and screws
    in seawater resistant robust stainless steel (AISI 316), M20 cable glands nickel-plated

Special model painted (coated) – ExCos-P-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel (AISI 316)
  • Learn more about ...Cos-P-CT

Special model painted (coated) – ExCos-P-...-OCT

  • Offshore version with aluminium housing offshore/marine coated, seawater resistant, cable glands nickel plated, tubes for clamping ring
    Ø 6 mm and screws in stainless steel (AISI 316)
  • Learn more about ...Cos-P-OCT

Accessories – ExCos-P..

  • Intrinsic, external LCD indicator connectable to ExCos-P..-A sensors, mounting in hazardous locations zone 1, 2, 21, 22
  • Mounting bracket for round air ducts up to Ø 600 mm
  • Installation kit with 2 m flexible pressure hose Ø 6 mm
  • Stainless steel pressure tube connection for 6 mm clamp fittings
  • M16 standard cable glands in brass nickel plated
  • M20 Ex-d cable glands in brass nickel plated for armoured cables
    (Offshore applications)
ExCos-D

Temperature-/humidity transmitter°C,%rH
Combination with ExPro-C.. sensors

Description – Analog temperature / humidity transmitter ExCos-D

  • Analog electric transmitter for measurements of temperature and/or humidity together with ExPro-C.. sensors in HVAC systems, installation in hazardous locations zone 1, 2, 21, 22
  • Connector for ExPro-C.. sensors for room or duct mounting
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Integrated actual value indication, illuminated, can be switched off
  • Integrated Ex-e terminal box
  • Robust aluminium housing with protection class IP66
  • Optional available in stainless steel (AISI 316) or with offshore/marine coating

ExCos-D

-40 °C...+125 °C0...100 %rHRoom- and / or duct measurement24 VAC / DC1 × ExPro-C.. Sensor0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHover integrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgGases, mists, vapours, dustZone 1, 2, 21, 22ATEX, IECEx, EAC, KOSHA

Delivery – ExCos-D..

  • 1 × Analog module ExCos-D with integrated Ex-e terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Required accessory: ExPro-C.. Sensor

Special models – ExCos-D-A

  • Module with two intrinsic 4..20 mA outputs to connect Ex-i external
    actual value indicator (Output 1 for °C, Output 2 for %rH)

Special model in stainless steel – ExCos-D-...-VA

  • Stainless steel housing AISI 316, some parts nickel plated

Special model painted (coated) – ExCos-D-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel (AISI 316)
  • Learn more about ...Cos-D-CT

Accessories – ExCos-D..

  • ExPro-C.. sensors
  • Intrinsic, external LCD indicator connectable to ExCos-D-A transmitter, mounting in hazardous locations zone 1, 2, 21, 22
  • Mounting bracket for round air ducts up to Ø 600 mm
  • Sensor extension cable 3 m
  • M16 standard cable glands in brass nickel plated
  • M20 Ex-d cable glands in brass nickel plated for armoured cables
    (Offshore applications)
ExPro-C.. sensors, compatible with ExCos-D / RedCos-D transmitter
ExCos-A

Temperature-/humidity transmitter°C,%rH
Combination with passive sensors

Description – Analog temperature / humidity transmitter ExCos-A

  • Analog electric transmitter for measurements of temperature or humidity together with analog passive ExSens sensors in HVAC systems, module installation in hazardous locations zone 1, 2, 21, 22
  • Connector for one ExSens sensor for room or duct mounting
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Integrated actual value indication, illuminated, can be switched off
  • Integrated Ex-e terminal box
  • Robust aluminium housing with protection class IP66
  • Optional available in stainless steel (AISI 316) or with offshore/marine coating

ExCos-A

24 VAC / DCAnalog, passive, potential free,
Type ExSens:
Pt 100, Pt 500, Pt 1000, Ni 100, Ni 200,
Ni 500, Ni 1000, Ni 1000 Siemens, KP 250, Resistance output 0...1 kOhm, 0...10 kOhm
0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHover integrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgGases, mists, vapours, dustZone 1, 2, 21, 22ATEX, IECEx, EAC, KOSHA

Delivery – ExCos-A..

  • 1 × Analog sensor ExCos-A with integrated Ex-e terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Required accessory: passive sensor, series ExSens

Special models – ExCos-A-A

  • Module with one additional intrinsically 4..20 mA output to connect a
    Ex-i external actual value indicator

Special model in stainless steel – ExCos-A-...-VA

  • Stainless steel housing AISI 316, some parts nickel plated

Special model painted (coated) – ExCos-A-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel (AISI 316)
  • Learn more about ...Cos-A-CT

Accessories – ExCos-A..

  • Intrinsic, external LCD indicator connectable to ExCos-A-A transmitter, mounting in hazardous locations 1, 2, 21, 22
  • Mounting bracket for round air ducts up to Ø 600 mm
  • M16 standard cable glands in brass nickel plated
  • M20 Ex-d cable glands in brass nickel plated for armoured cables
    (Offshore applications)
back to Product choice
to the top

Schischek News

New content on Schischek Homepage

Colour Code

ATEX products for
zone 1, 2, 21, 22
(e.g. ExMax+LIN)

ATEX products for
zone 2, 22
(e.g. RedMax+LIN)

Products for
safe area
(e.g. InMax+LIN)

Offshore/Marine
Coated versions
(e.g. ..Bin..-CT / OCT)

Stainless steel versions AISI 316
(e.g. ExCos-V)